Description
GENERAL SPECIFICATION
Display: 3 1/2 digit LCD with a max,reading of 1999
Overrange indication:”1”shown on LCD
Sampling Rate:Approximate 3 times per sec.
Error caused by improper position: Reading 1%
(Note:The conductor should be placed in the center of the area closed
by the jaws to avoid this error)
Sensor:Clamp-shape transformer for AC measurement.
Jaw opening capabiity:27mm
Max.measurable conductor:Diemen.25mm
Battery:3V,CR2032,three batteries.
Operation temperature:0~40 degree C,<75%RH
Storage temperature:-20~60 degree C,<85%RH
Szie:151mmx65mmx34mm
Weight:about 120g( not including battery)
SPECIFICATION
AC Voltage
Range |
Resolution |
Accuracy |
Overload Protection |
600V |
1V |
±(1.2%+3) |
DC 600V AC 600Vrms |
Input impedance:9MΩ
Frequency response:40Hz~400Hz
Max.permitted input voltage:600Vrms
DC Voltage
Range |
Resolution |
Accuracy |
Overload Protection |
600V |
1V |
±(1.2%+2) |
DC 600V AC 600Vrms |
Input impedance:9MΩ
Max.permitted input voltage:600Vrms
AC Current
Range |
Resolution |
Accuracy |
Overload Protection |
20A |
10mA |
±(1.2%+3) |
500A(30secs.) |
200A |
100mA |
±(2.5%+5) |
|
400A |
1A |
Response:Average,calibtated in rms of sine wave.
Frequency range:50~60Hz
Resistance
Range |
Resolution |
Accuracy |
Overload Protection |
2000Ω |
1Ω |
±(1.2%+2) |
DC 250V AC 250Vrms |
200kΩ |
100Ω |
±(1.5%+2) |
Audible Continuity
Range |
Resolution |
Accuracy |
|
1Ω |
If the resistance is less than about 30Ω,the buzzer will sound. |